×

NIJ  0108.01

US National Institute of Justice Standard-Test and Certification for Ballistic Resistant Materials

This US specification is applicable to all ballistic resistant materials (armour) intended to provide protection against gunfire, with the exception of police body armour and ballistic helmets, which are the topic of individual NIJ performance standards.  The calibre of weapons are similar to that of the European EN1063 and US UL752 standard but have different categories which can be seen in the document to the right.

Architectural Armour offer a range of NIJ 0108.01 window and glass options.  If you have any questions about your requirements, please feel free to email mailto:info@architecturalarmour.com or call us on +44(0)1981 257000 .

To view the products that can incorporate NIJ 0108.01 bullet resistant glass or have been tested to this standard see the below links .

Stock items 

Bullet Resistant Door Viewer                                     A full range of bulletproof / Resistant Door Viewers / Peepholes / Spyholes BR4 to BR6

Bespoke items 

Bullet Resistant Windows                                           Ballistic windows to resist bullets from 9mm Luger to 7.62 AP                                                    

Security Counters and Screens                                Physical, Ballistic or Blast resisting counters for any application to keep staff secure

Ballistic and Blast Resistant Guard Houses        Modular New Build or Upgrading existing. EN1522/3 FB2 to FB7 , NIJ 0108.01 LII to IV UL 752

Bullet Resistant Doors                                                   A range of fully tested and certified ballistic single and double doors. 

To download this standard, or view in a separate window, please click on the link .

        NIJ 0108.1 Ballistic Resistant Materials Standard

 For our full range of technical specifications please click on relevant headings below; 

 

Other Ballistic Technical Specifications

EN 1063               Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack

UL 752                   Standard for Bullet-Resisting Equipment

BS 5051                Bullet-resistant glazing - Part 1:  for interior use- Part 2: for Exterior use

EN 1522/3          Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification /Test method

Blast Specifications

GSA-TS01:2003     Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings

EN 13541                   Glass in building - Security glazing - Testing and classification of resistance against explosion pressure 

EN 13123-2               Windows, doors and shutters - Explosion resistance - Requirements and classification

ISO 16933:2007  Glass in Building -- Explosion-Resistant Security Glazing -- Test & Classification for Arena Air-Blast Loading

Fire Specifications

UL 10C           Positive Fire Pressure Tests of Door Assemblies 

EN 1363-1    Fire resistance tests –Part 1: General Requirements

EN 1364-1     Fire resistance tests for non-load-bearing elements – Part 1: Walls

BS 476 Part 22     Fire tests on building materials and structures

EN 1634-1   Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware 

Manual Attack  Specifications

EN 1627   Pedestrian door-sets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification

LPS 1270   Intruder Resistant Security Glazing -  Requirements & Testing Procedures 

LPS 1175 Requirements and testing procedures for the LPCB certification and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers

EN 356         Glass in building - Security glazing - Testing and classification of resistance against manual attack.

LPS 1175 and 1270 Tool Categories   Testing procedures for the LPCB approval

 

 

 

This is an extract not a full report and Architectural Armour Ltd accepts no liability for any loss, direct, indirect or consequential damage incurred by using this information, to the fullest extent permitted by law. You should make your own judgement as regards use of this document and seek out the full test standards. 

Latest News

Split Height Transaction Window Duo 

Using experience on previous projects and customers requirements we have designed a split height transaction window offering standing and DDA access to reception and data centre environments.

2 Position Screen

 

For more information and pricing please contact our office on info@architecturalarmour.com or +44(0)1981 257000

 

 

Read more

Increased Stock for Express Delivery

We have increased our range of stock transaction windows to six units , ready for express dispatch.

Our range of transaction windows include, physical attack resistant and bullet resistant internal and external models. Please see below an outline of our products.

Architectural Armour are offering standard stock items and bespoke orders to suit.  Please contact us on +44(0) 1981 257000 

 

 

Stock Transaction Windows

 

 

 

 

 

 

 

 

 

 

 

 

Read more